Nitsol Bangladesh Ltd
24/7 | NITSOL WATCHINGContactProtect my locations
SERVICES / ENERGY MANAGEMENT
Energy Management System

Monitor, control, and automate your site.

Watch temperature, doors, and smoke. Command AC, lights, fans, and any electric device from one platform. AI rules act for you; every event hits POST /data with a clear audit trail.

AI-powered EMS
Nitsol AI EMSMONITOR · CONTROL · AUTOMATE

AI watches the sensors. You control the site.

Temperature, doors, and smoke feed the same platform that can switch AC, lights, fans, and any relay-backed device. Rules run automatically; every change is logged to POST /data.

Smart thresholds
AI learns normal temperature and power bands per zone so alerts are meaningful, not noisy.
Correlated events
Door_open + temperature spike + camera motion can be evaluated together before escalation.
Safety-first rules
Smoke alerts can trigger device shutdown, notifications, and handoff to surveillance operators.
Scheduled automation
After-hours: lights off, fans down, AC in economy mode unless an exception is detected.
AI Smart Site | live
AC Zone 2
ON
Loading lights
OFF
Fan bank A
ON
Server room door
OPEN
Rack temp
27.3°C
Smoke sensor
CLEAR
AI RULES ENGINE
IF temp > 30°CTHEN ac_zone_2 = onactive
IF door_open + after_hoursTHEN alert + camera verifyactive
IF smoke = detectedTHEN cut relay_line_3, notify allarmed
IF no motion 30mTHEN lights off, fan_bank offactive
What we monitor

Sensors that keep you ahead.

Environmental, access, and safety inputs stream in continuously. Door and smoke events can trigger alerts, device actions, and camera verification.

TEMP

Temperature monitoring

Room, rack, and cold-chain probes with high/low thresholds and trend graphs.

DOOR

Door sensors

Magnetic contacts on doors, gates, and cabinets. Instant door_open alerts in the log.

SMOKE

Smoke detection

Smoke and heat sensors tied into EMS and, when configured, fire escalation paths.

ENV

Humidity & air quality

Humidity, pressure, and optional air-quality inputs for storage and plant rooms.

POWER

Power metering

Voltage, current, and power draw per circuit or cabinet for load visibility.

PIR

Motion & occupancy

Optional PIR inputs to drive lights, AC, or after-hours rules with AI.

What we control

AC, lights, fans, and more.

If it runs on electricity and connects to our gateway or relay, you can schedule it, switch it remotely, or let AI run it from sensor data.

Air conditioning (AC)

Turn zones on or off, set schedules, or let AI cool a room when temperature crosses your limit.

ac_zone_2 → on

Lighting

Relays and smart switches for floors, yards, and security lighting tied to time or sensor rules.

light_loading_bay → off

Fans & ventilation

Exhaust fans, circulation fans, and plant ventilation banks from one control plane.

fan_bank_a → on

Any electric load

Contactors and IoT relays for pumps, heaters, signage, or custom equipment on site.

relay_line_3 → off
Audit log

Every sensor read and device command, logged.

sensor_report, alert, device_control, and ai_rule events all POST to /data and return 200 OK when accepted.

sensor_reportalertdevice_controlai_rule
EMS INGEST | POST /dataLIVE
TimeSource IPPathTypeDataStatus
18:58:47127.0.0.1/dataPOSTInternal/local health check200 OK
18:59:4737.111.203.192/datasensor_reporttemp=27.3°C, humidity=54.9%, pressure=998.7 hPa, voltage=220.0V, current=1.20A, power=264.0W200 OK
19:00:1237.111.203.192/datadevice_controldevice=ac_zone_2, action=on, reason=ai_temp_high200 OK
19:00:4637.111.203.192/datasensor_reporttemp=27.0°C, humidity=55.0%, pressure=998.7 hPa, door=closed, smoke=clear200 OK
19:00:4837.111.203.192/dataalertreason=door_open, zone=server_room200 OK
19:01:0237.111.203.192/dataai_rulerule=cooldown_after_hours, action=fan_bank_off, confidence=0.94200 OK
Live metrics

Full environmental and power snapshot.

Temperature
27.3°C
Humidity
54.9%
Pressure
998.7 hPa
Voltage
220.0V
Current
1.20A
Power
264.0W
Alerts

Door, smoke, temperature, and offline.

reason=door_open

Door, gate, or cabinet opened. Pair with cameras for instant verification.

reason=smoke_detected

Smoke or heat threshold breached. Can trigger relays off and emergency contacts.

reason=temp_threshold

Room or rack temperature above or below your configured band.

reason=device_offline

Gateway or sensor stopped reporting. Know before blind spots grow.

Pair EMS with AI E-Surveillance: door_open or smoke_detected can alert our monitoring team to verify on camera and act per your protocol.

See managed monitoring
Sites

Built for real facilities.

Plant & utility rooms

Monitor heat and power, control ventilation, get smoke alerts before damage spreads.

Warehouses & cold storage

Temperature and door sensors on cold rooms with fan and light automation.

Server & telecom sites

Rack temperature, door contacts, and AC control with audit logs for every change.

Branches & secure rooms

Door and environmental monitoring linked to AI surveillance when you need eyes on site.

FREE SECURITY AUDIT

Send a Nitsol professional to assess your premises.

Tell us about your location - our team visits, walks the premises, and gives you a written security audit. No software to install, no obligation.